Zodiac Jandy Legacy LRZ Millivolt Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Oberirdisches Schwimmbadzubehör Zodiac Jandy Legacy LRZ Millivolt herunter. Zodiac Jandy Legacy LRZ Millivolt Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed
and qualied in pool equipment by the jurisdiction in which the product will be installed where such
state or local requirements exists. In the event no such state or local requirement exists, the installer
or maintainer must be a professional with sufcient experience in pool equipment installation and
maintenance so that all of the instructions in this manual can be followed exactly. Before install-
ing this product, read and follow all warning notices and instructions that accompany this product.
Failure to follow warning notices and instructions may result in property damage, personal injury,
or death. Improper installation and/or operation can create carbon monoxide gas and ue gases
which can cause serious injury, property damage, or death. For indoor installations, as an additional
measure of safety, Zodiac Pool Systems, Inc. strongly recommends installation of suitable Carbon
Monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces. Improper
installation and/or operation will void the warranty.
Installation and
Operation Manual
Legacy™
Pool and Spa Heater
Model LRZ Millivolt
Natural Gas or LPG
WARNING
Read this manual in its entirety. If these instructions are not followed exactly, a re
or explosion may result, causing property damage, personal injury, or death.
The GAS SAFETY (INSTALLATION AND USE) REGULATIONS 1998, as amended,
place statutory requirements on gas users.
This heater is certied to European requirements for use only as a swimming pool
or spa heater. The heater must not be used for any other purpose and must be
installed and serviced by a qualied professional. The heater must be operated
strictly in accordance with the user's instructions and applicable laws. If the heater
is installed in a room it must be separated from a living space, adequate air supply
and ventilation must be provided and maintained.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity
of this or any other appliance.
Installation and Operation Data
H0316500BetaB
Note: LPG for Outdoor Use Only
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - H0316500BetaB

WARNINGFOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualied in pool equipment by the jurisdicti

Seite 2

Page 10Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualcombustible surfaces (see Table 3).At least 457 mm access must be available

Seite 3 - Table of Contents

Page 11Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualmust be open on three (3) sides. This prevents combus-tion gases from being

Seite 4 - Table of Contents (Continued)

Page 12Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualconjunction with a 50 mm (minimum) thick layer or vermiculite or perlite gr

Seite 5 - 1.1 Introduction

Page 13Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualsuch as "The Gas Safety (Installation and Use) Regulations" (Stat

Seite 6

Page 14Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manual4.2 Burner PressureConrm that gas supply pressure is correct. If the gas

Seite 7 - 2.1 Introduction

Page 15Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualtechnician. Heat exchanger reversals are generally done before the installa

Seite 8 - 2.2. Statutory Information

Page 16Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualtion reversal is illustrated in Figures 8 and 9. Proceed as follows: 1. Fo

Seite 9 - 2.5.2 Clearances

Page 17Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualed tubes on the right side of the tube assembly. Align the bolt and tube ho

Seite 10 - 2.5.4 Outdoor Installation

Page 18Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualnot endanger anyone near the heater. Refer to your local installation codes

Seite 11 - Section 3. Venting

Page 19Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualthe following:• When ozone is injected upstream of the heater, install an

Seite 13 - Burner Pressure

Page 20Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualThe equipment and/or appliances associated with the pool water circulating

Seite 14 - Section 5. Water Connections

Page 21Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualSection 7. Commissioning7.1 Heater Start-Up1. When the heater has lit, r

Seite 15 - LRZ Pressure Drop vs. Flow

Page 22Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualThe heater may not start on the rst try. Air in the gas line or other star

Seite 16

Page 23Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualFigure 19. Legacy Lighting and Shutdown ProceduresH0320600Beta-WARNING: If

Seite 17 - 5.7 Pressure Relief Valve

Page 24Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manual8.3.2 Relighting the HeaterIf the pilot goes out, repeat steps 5 through 7

Seite 18 - 5.8 Auxiliary Components

Page 25Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualring. As the pool/spa water temperature falls below the thermostat setting

Seite 19 - Section 6. Electrical

Page 26Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manual5. After all water has drained from the heater, check for mineral buildup

Seite 20 - 6.25W x 4.25H

Page 27Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualheater's safe and efcient operation. The following basic safety check

Seite 21 - Section 7. Commissioning

Page 28Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualSection 10. Troubleshooting10.1 General Heater TroubleshootingTable 8 lis

Seite 22 - 8.2 Start-Up

Page 29Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualTable 8. Legacy Troubleshooting Guide#Symptom Cause Remedy1. Pump not oper-

Seite 23 - LIGHTING INSTRUCTIONS

Page 3Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualSection 1. General Information ... 51.1 Introduction ...

Seite 24 - 8.3.3 Shut-Down Procedure

Page 30Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualSection 11. Professional Maintenance and Service WARNINGSERVICING SAFET

Seite 25 - Section 9. Maintenance

Page 31Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualbroken at any time, the gas valve is immediately shut off and the heater st

Seite 26 - DRAIN PLUG

Page 32Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualFigure 25. Test Point Identication DiagramTEMPERATURE CONTROLFUSIBLE L

Seite 27

Page 33Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manual11.4.2 Pilot GeneratorThe pilot generator generates a 700-750mVDC signal w

Seite 28 - Section 10. Troubleshooting

Page 34Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualswitch has a poor or broken connection or a partial short. Replace the wire

Seite 29 - Symptom Cause Remedy

Page 35Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualFigure 26. Pressure Switch AdjustmentBYPASS ADJUSTMENT SCREWTHERMOMETER WIT

Seite 30 - Maintenance and Service

Page 36Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualor more. Note and record the thermometer reading. Subtract pool water tempe

Seite 31 - 11.4.1 Gas Valve

Page 37Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualsKey No. DescriptionModel No. Order Part No.Pilot/Igniter System1 Pilot, Ma

Seite 32

Page 38Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manual12.3 General Exploded View414243275745383937406268676646735859606164657463

Seite 33 - 11.4.5 Limit Switches

Page 39Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manual12.4 Detailed Exploded View49543132525136505654491135530717212322181915121

Seite 34 - 11.4.6 Water Pressure Switch

Page 4Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualSection 10. Troubleshooting ... 2810.1 General Heater Troub

Seite 35 - 11.6 Temperature Rise

H0316500BetaBZodiac Pool Systems, Inc.6000 Condor Drive, Moorpark, CA, USA 93021 • 800.822.7933 FAX 877.327.1403 © 2010 Zodiac Pool Syste

Seite 36 - 12.1 Ordering Information

Page 5Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualSection 1. General Information1.1 IntroductionThis manual provides install

Seite 37 - 12.2 Parts List

Page 6Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manual1.2.2 Swimming Pool Energy Saving TipsZodiac Pool Systems, Inc., ("Zod

Seite 38 - 12.3 General Exploded View

Page 7Legacy™ Model LRZM Pool/Spa Heater Installation and Operation ManualNoncombustible bases are available from your Jandy distributor.4. A factory

Seite 39 - 12.4 Detailed Exploded View

Page 8Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manual5. Proper electrical wiring (if required)6. Adequate water owThis manual

Seite 40 - LIMITED WARRANTY

Page 9Legacy™ Model LRZM Pool/Spa Heater Installation and Operation Manualwise recommended in writing by Zodiac, if in doubt please ask. Any direct co